D9 fault code and solution
Fault code |
Fault description |
Cause of malfunction |
Solution to the malfunction |
ER-01 |
Unable to find needle stop position |
1: The handwheel and motor are not close enough 2: The magnetic steel on the handwheel has fallen off 3: Reverse polarity installation of handwheel magnet 4: Poor contact of the nine pin terminal head 5: Motor Hall is damaged |
1: Check if the motor signal wire is loose 2: Replace the handwheel 3: Replace the motor
|
ER-02 |
Governor signal error |
1: When starting up, the speed controller was not plugged in 2: Reverse insertion of speed regulator 3: Governor wire disconnected |
1: Check the signal line of the speed controller 2: Replace the speed regulator 3: Replace the controller |
ER-03 |
Motor phase signal error |
1: Poor contact of the nine pin plug 2: There is a significant deviation between the Hall sensor and the rotor during motor installation 3: The motor Hall is broken |
1: Open the rubber cover on the motor and look at the motor through the hole Is the rotor and stator in the same plane to ensure error Not exceeding 1MM 2: Replace the motor 3: Replace the controller |
ER-04 |
Motor stalling protection |
1: Sewing machine is too heavy or blocked The 4-wire drive cable is not connected properly or plugged in incorrectly |
1: Check the 4P wire of the motor |
ER-05 |
Hardware overcurrent protection |
1: Sewing machine is too heavy or blocked |
|
ER-07 |
Display screen and motherboard communication timeout |
1: Poor connection of the display screen to the motherboard cable |
1: Check the connection cable between the display screen and the controller |
ER-09 |
Poor memory |
1: Damaged or faulty motherboard memory |
1: Controller damage 1: Control box damage |
ER-10 |
Optical eye control circuit malfunction |
1: The display screen is poorly connected to the optical eye |
1: Display screen damaged |
ER-15 |
encoder failed |
||
ER-16 |
Overvoltage |
The motor drive power supply voltage is too high, the 220V power supply voltage exceeds the limit value (AC310V), or the load inertia is too large, leading to the regeneration voltage exceeding the limit value (DC440V), or the voltage detection circuit is faulty. |
|
ER-17 |
A-phase current detection fault |
||
ER-18 |
B-phase current detection fault |
||
ER-19 |
AB phase current detection fault |
||
ER-20 |
Undervoltage fault |
1. The voltage of the motor drive power supply is too low, the voltage of the 220V power supply is below the limit value (AC91V), or the voltage of the motor drive power supply is below the limit value (DC130V), or the voltage detection circuit is faulty. |